Safety in your working environment
|
With METTLER TOLEDO hazardous area solutions, apparent contrasts turn into one set of standards. Our wide selection of intrinsically safe weighing systems embraces balances, indicators and accessories, weigh modules, and weighing platforms of any size, shape and capacity.
Bestill mer informasjon Bestill et tilbud |
We ensure full safety with globally approved equipment for explosive environments classified as Zone 1 and 21, or Division 1 and Zone 2 and 22, or Division 2.
All weighing solutions can be seamlessly integrated into the process landscape to increase your productivity and to meet your claim for tight product quality.
Produkter
| Degree of protection | Hazardous area approval | ||
| DB30sTx | IP67 | 2 G/D | |
| DB30sx | IP67 | 2 G/D | |
| DB60sTx | IP67 | 2 G/D | |
| DB60sx | IP67 | 2 G/D | |
| DCC150sTx | IP67 | 2 G/D | |
| DCC150sx | IP67 | 2 G/D | |
| DCC300sTx | IP67 | 2 G/D | |
| DCC300sx | IP67 | 2 G/D | |
| KA15sx | IP66/67 | II 2G EEx ib IIC T4, II2D IP67 T+55°C; Class I,II,III, Div. 1, Group A-G | |
| KA32sx | IP66/67 | II 2G EEx ib IIC T4, II2D IP67 T+55°C; Class I,II,III, Div. 1, Group A-G | |
| KB60sx | IP66/67 | II 2G EEx ib IIC T4, II2D IP67 T+55°C; Class I,II,III, Div. 1, Group A-G | |
| KB60 x | IP66/67 | II 2G EEx ib IIC T4, II2D IP67 T+55°C; Class I,II,III, Div. 1, Group A-G | |
| KCC150sx | IP66/67 | II 2G EEx ib IIC T4, II2D IP67 T+55°C; Class I,II,III, Div. 1, Group A-G | |
| KCC150x | IP66/67 | II 2G EEx ib IIC T4, II2D IP67 T+55°C; Class I,II,III, Div. 1, Group A-G | |
| KCC300sx | IP66/67 | II 2G EEx ib IIC T4, II2D IP67 T+55°C; Class I,II,III, Div. 1, Group A-G | |
| KCC300x | IP66/67 | II 2G EEx ib IIC T4, II2D IP67 T+55°C; Class I,II,III, Div. 1, Group A-G | |
| PBA430x-A15 | analog: IP68/69k | category 2 G/D | |
| PBA430x-A3 | analog: IP68/69k | category 2 G/D | |
| PBA430x-A6 | analog: IP68/69k | category 2 G/D | |
| PBA430x-B150 | analog: IP68/69k | category 2 G/D | |
| PBA430x-B30 | analog: IP68/69k | category 2 G/D | |
| PBA430x-B60 | analog: IP68/69k | category 2 G/D | |
| PBA430x-BB30 | analog: IP68/69k | category 2 G/D | |
| PBA430x-BB60 | analog: IP68/69k | category 2 G/D | |
| PBA430x-BC150 | analog: IP68/69k | category 2 G/D | |
| PBA430x-BC300 | analog: IP68/69k | category 2 G/D | |
| PBA430x-BC60 | analog: IP68/69k | category 2 G/D | |
| PBA430x-CC150 | analog: IP68/69k | category 2 G/D | |
| PBA430x-CC300 | analog: IP68/69k | category 2 G/D | |
| PBA430x-CC60 | analog: IP68/69k | category 2 G/D | |
| PBA430x-CC600 | analog: IP68/69k | category 2 G/D | |
| PBA430x-QA6 | analog: IP68/69k | category 2 G/D | |
| PBA430x-QB15 | analog: IP68/69k | category 2 G/D | |
| PBA430x-QB30 | analog: IP68/69k | category 2 G/D | |
| PBA430x-QB60 | analog: IP68/69k | category 2 G/D | |
| PBA430x-QC150 | analog: IP68/69k | category 2 G/D | |
| PBA430x-QC60 | analog: IP68/69k | category 2 G/D | |
| Viper Ex DR 15 L - intrinsically safe compact scale | IP43 standard | yes | |
| Viper Ex DR 35 L - intrinsically safe compact scale | IP43 standard | yes | |
| Viper Ex DR 3 S - intrinsically safe compact scale | IP43 standard | yes | |
| Viper Ex DR 60 L - intrinsically safe compact scale | IP43 standard | yes | |
| Viper Ex DR 6 S - intrinsically safe compact scale | IP43 standard | yes | |
| Viper Ex MB 15 L - intrinsically safe compact scale | IP43 standard | yes | |
| Viper Ex MB 35 L - intrinsically safe compact scale | IP43 standard | yes | |
| Viper Ex MB 3 X - intrinsically safe compact scale | IP43 standard | yes | |
| Viper Ex MB 6 S - intrinsically safe compact scale | IP43 standard | yes |